Model IP - Pipe-Type Reference

Typical Application Featuring

Housing Specifications
0.840 inch (21.3 cm) dia. at termination end
1.0 inch (2.5 cm) dia. x 3 1/4 inch (8.3 cm) long PVC
Shipping weight without wire - 1/2 lb (1/4 kg)
Element Type
AGD - dry-type Ag/AgCl
ZIN - 99.99% zinc
Termination
ST - 1/4-20 threaded stud
SW - 25 ft (7.5m). #18 AWG PVC insulated test lead
LWnnn - additional lead wire in 25 ft.increments
Model Designation
Specify as EDI Model IP-xxx-yy
xxx = Element type
yy = Termination type

Design Compatibility
The Model IP is a compact, economical, dry-type reference electrode for marine applications. It has a 0.840 inch (21.3 cm) diameter PVC bushing on the termination end. This enables the user to cement on any ½ inch socket-end PVC pipe or electrical conduit fitting (e.g. male or female conduit thread or couplings) for permanent installation. Examples of this are shown on EDI Drawing IPAPP2 where ½ inch PVC couplings serve as transition pieces for running the lead wire through conduit or attaching the electrode to a wall. For intermittent use, the Model IP has a blind 1/4-20 tapped hole for attaching up to a 5 lb (2 kg) weight. Should more weight than that be necessary, the electrode and the weight should be attached to a separate drop line as shown on EDI Drawing IPAPP1.